call scientifica_uk
LiveZilla Live Help

Live Chat

+44 (0)1825 749933

  • New SliceScope Pro video series: Dale Elgar talks through the SliceScope Pro Microscopy systems in our new video series. > Discover the SliceScope Pro

  • Brand new MicroStar Manipulator: Struggling to fit your Manipulators round your sample? The MicroStar is ideal for synaptic connectivity & networks. > More information here

  • News & Views from the Electrophysiology Experts Join our mailing list for monthly research articles, latest Scientifica updates and competitions! Sign up here!

  • Multi Channel Systems Wireless in vivo system: The W8 is the all in one wireless solution for amplifying, recording and analyzing in vivo data. > Find out more here

  • Looking for tomorrow's genius?: Place an ad on our research job pages, just for electrophysiologists and free to use > Research jobs 

pCLAMP 10

Conventional Electrophysiology Data Acquisition and Analysis Software

The pCLAMP 10 software suite fulfills many different experimental needs, such as synchronized stimulation, event detection, and online analysis. It is the most widely-used data acquisition and analysis program for the control and recording of voltage-clamp, current-clamp, and patch-clamp experiments. Three separate programs are included: Clampex 10, AxoScope 10, Clampfit 10.

Clampex 10 expands the range and quality of your data acquisition experiments. These improvements should prove useful for a wide variety of applications, allowing more flexibility in your experimental protocols.

New features include:

  • Membrane Test calculates Ra and Cm per sweep during a recording
  • Membrane and Seal Tests combined into a single resizable window
  • Support for four stimulus waveforms (with the Digidata 1440A)
  • Control of eight digital outputs per epoch during a sweep
  • Control of split-clock sampling per epoch during a sweep
  • Leak subtraction automatically saves both raw and corrected traces
  • All protocol durations are entered in time units
  • Support of the new Digidata 1440A digitizer
  • Support of the new Axoclamp 900A amplifier
  • New ABF 2.0 file format

Existing functionality includes the ability to automate the execution of protocols, a variety of recording modes from continuous to waveform stimulation, online filtering and leak subtraction, and online statistics/graphs. AxoScope10 provides a convenient way to produce background recordings with the included MiniDigi 2-channel digitizer*. You can monitor cells during intra-sweep periods, or create an overview of the entire day's activities including voice tags.

Clampfit 10 is a powerful solution for analyzing, graphing and layout of all of your Clampex and AxoScope data. Clampfit includes an extensive array of filtering and fitting routines. Functionality includes I-V graphs, power spectrums, and special "linked data views" for threshold (AP), template (minis) and single-channel modes of event detection and analysis.

Conventional Electrophysiology Data Acquisition and Analysis Software

The pCLAMP 10 software suite fulfills many different experimental needs, such as synchronized stimulation, event detection, and online analysis. It is the most widely-used data acquisition and analysis program for the control and recording of voltage-clamp, current-clamp, and patch-clamp experiments. Three separate programs are included: Clampex 10, AxoScope 10, Clampfit 10.

Clampex 10 expands the range and quality of your data acquisition experiments. These improvements should prove useful for a wide variety of applications, allowing more flexibility in your experimental protocols.

New features include:

  • Membrane Test calculates Ra and Cm per sweep during a recording
  • Membrane and Seal Tests combined into a single resizable window
  • Support for four stimulus waveforms (with the Digidata 1440A)
  • Control of eight digital outputs per epoch during a sweep
  • Control of split-clock sampling per epoch during a sweep
  • Leak subtraction automatically saves both raw and corrected traces
  • All protocol durations are entered in time units
  • Support of the new Digidata 1440A digitizer
  • Support of the new Axoclamp 900A amplifier
  • New ABF 2.0 file format

Existing functionality includes the ability to automate the execution of protocols, a variety of recording modes from continuous to waveform stimulation, online filtering and leak subtraction, and online statistics/graphs. AxoScope10 provides a convenient way to produce background recordings with the included MiniDigi 2-channel digitizer*. You can monitor cells during intra-sweep periods, or create an overview of the entire day's activities including voice tags.

Clampfit 10 is a powerful solution for analyzing, graphing and layout of all of your Clampex and AxoScope data. Clampfit includes an extensive array of filtering and fitting routines. Functionality includes I-V graphs, power spectrums, and special "linked data views" for threshold (AP), template (minis) and single-channel modes of event detection and analysis.

pCLAMP 10 is suitable for a wide variety of applications, ranging from electrophysiology to general physiology, from individual cells to networked cells, and from low-noise patch clamping to high-speed sodium channels.

Applications include:

  • Action Potentials (APs)
  • Current-clamp
  • Electromyography (EMG)
  • Electrooculography (EOG)
  • Excitatory Post-Synaptic Currents (EPSCs)
  • Excitatory Post-Synaptic Potentials (EPSPs)
  • Inhibitory Post-Synaptic Currents (IPSCs)
  • Inhibitory Post-Synaptic Potentials (IPSPs)
  • Long-Term Depression (LTD)
  • Long-Term Potentiation (LTP)
  • Miniature excitatory potentials (Minis)
  • Ratio dyes (with PMTs)
  • Single-channels
  • Slices
  • Spike trains
  • Synaptic networks
  • Voltage-clamp
  • Whole-cell

A sample screenshot from the pCLAMP10 interface:

pCLAMP_10_large

Twitter_icon Youtube_icon